Model 244 pneudraulic installation tool · Installation tool · Huck
244 installs NAS shear pull-type lockbolt -4, -5, -6 with nose 99-2651, 99-2549S, 99-2550S, 99-2555 or 99-2556.
3D model not available: dimensions not published. 3D library
Everything it installs1 fastener group
NAS shear pull-type lockbolt (pin and collar) -4, -5, -6, per the Huck catalog
Other brands' equivalents1 statement
- Gage Bilt says GB731 replaces 244 (Huck) Gage Bilt 2017 p.106 ↗
Gage Bilt's cross-reference lists GB731 (installation tool) for 244.
Sources2
- Huck Aerospace Installation Equipment catalog (Jan 2010, archived), p.46, Model 244, Standard Inline & Offset Nose Assemblies ↗
- Model 244, Standard Inline & Offset Nose Assemblies.
- Model 244, Standard Inline & Offset Nose Assemblies. "Requires Adapter Part Number 128279. No Stroke Limiter Needed".
- Gage Bilt Aerospace Catalog 2017 (archived; pages are PDF pages), p.106, Other - Gage Bilt Cross Reference, page 1 ↗
Tool catalogs are the manufacturers' as published in the cited edition; confirm current PNs with the tool maker before purchase. Install per the OEM process specification.
Published dimensions5 · for envelope CAD
| Feature | Value | As printed | Source |
|---|---|---|---|
| Stroke | 0.562 in | Stroke: .562 in | Huck Aerospace Installation Equipment catalog (Jan 2010, archived), p.90, 244 Series Tooling specifications ↗ |
| Weight | 5.69 lb | Weight: 5.69 lbs | Huck Aerospace Installation Equipment catalog (Jan 2010, archived), p.90, 244 Series Tooling specifications ↗ |
| Air pressure | 90 psi | Air Pressure: 90-100 psi | Huck Aerospace Installation Equipment catalog (Jan 2010, archived), p.90, 244 Series Tooling specifications ↗ |
| Air consumption | 6.3 scfm | Air Consumption: 6.3 SCFM | Huck Aerospace Installation Equipment catalog (Jan 2010, archived), p.90, 244 Series Tooling specifications ↗ |
| Pull force | 4606 lbf | Capacity: 4606 lbs @ 90 psi | Huck Aerospace Installation Equipment catalog (Jan 2010, archived), p.90, 244 Series Tooling specifications ↗ |
Only dimensions a document prints are listed, with the feature each one measures. A length read from a part number by a rule the cited chart prints is marked "Not printed as a number". None of these catalogs publishes nose tip or anvil geometry detailed enough to machine from.
Reference only: the controlling drawing, its process spec and the manufacturer's installation instructions govern. How to use these answers
Next step
Free to ask. A person at SpecLok replies by email. You only pay the supplier if you accept a quote.