Radial-Lok tooling, gauges and removal
Monogram · Blind bolt · Family page · Shop verification card
By diameter
| Dia. | Published tool + nose | Other access | Gauges |
|---|---|---|---|
| -6 | MP550RL-6AA (MP550RL + MPPBF-8 + MPBF-6) | Right angle | RLS-1A, MRLG-6, MGFRL-6 / MGPRL-6 |
| -8 | MP550RL-8AA (MP550RL + MPPBF-8 + MPBF-8) | Right angle | RLS-1A, MRLG-8, MGFRL-8 / MGPRL-8 |
| -10 | MP550RL-10AA (MP550RL + MPP-12 + MPTRL-10) | None published | RLS-1A, MRLG-10, MGFRL-10 / MGPRL-10 |
| -12 | MP550RL-12AA (MP550RL + MPP-12 + MPTRL-12) | None published | RLS-1A, MRLG-12, MGFRL-12 / MGPRL-12 |
Tools, heads, adapters and gaugesCited tables
Published tool combinations
- Dia.Tool + nose / headAccessNotes and source
- -6MP550RL-6AA (MP550RL + MPPBF-8 + MPBF-6)Standard · pneumaticWrench adapter (turns screw) MPBF-6; nose adapter (holds nut) MPPBF-8.Monogram MRL1003 (Radial-Lok install spec), p.6, Table 1 ↗
- -7MP550RL-7AA (MP550RL + MPPBF-8 + MPBF-7)Standard · pneumaticWrench adapter (turns screw) MPBF-7; nose adapter (holds nut) MPPBF-8.Monogram MRL1003 (Radial-Lok install spec), p.6, Table 1 ↗
- -8MP550RL-8AA (MP550RL + MPPBF-8 + MPBF-8)Standard · pneumaticWrench adapter (turns screw) MPBF-8; nose adapter (holds nut) MPPBF-8.Monogram MRL1003 (Radial-Lok install spec), p.6, Table 1 ↗
- -9, -10MP550RL-10AA (MP550RL + MPP-12 + MPTRL-10)Standard · pneumaticWrench adapter (turns screw) MPTRL-10; nose adapter (holds nut) MPP-12.Monogram MRL1003 (Radial-Lok install spec), p.6, Table 1 ↗
- -11, -12MP550RL-12AA (MP550RL + MPP-12 + MPTRL-12)Standard · pneumaticWrench adapter (turns screw) MPTRL-12; nose adapter (holds nut) MPP-12.Monogram MRL1003 (Radial-Lok install spec), p.6, Table 1 ↗
- -6MRT550RL-6AA (MRT550RL + MRTPRL-8 + MRTRL-6)Right angle · pneumaticWrench adapter MRTRL-6; nose adapter MRTPRL-8.Monogram MRL1003 (Radial-Lok install spec), p.7, Table 2 ↗
- -7MRT550RL-7AA (MRT550RL + MRTPRL-8 + MRTRL-7)Right angle · pneumaticWrench adapter MRTRL-7; nose adapter MRTPRL-8.Monogram MRL1003 (Radial-Lok install spec), p.7, Table 2 ↗
- -8MRT550RL-8AA (MRT550RL + MRTPRL-8 + MRTRL-8)Right angle · pneumaticWrench adapter MRTRL-8; nose adapter MRTPRL-8.Monogram MRL1003 (Radial-Lok install spec), p.7, Table 2 ↗
Installation tools
MP550RL
MP 550 RL Pneumatic Pistol
pneumatic
Monogram MRL1003 (Radial-Lok install spec), p.6, Figure 1, Table 1 ↗
MRT550RLRight angle
MRT550 RL Pneumatic Right Angle Torque Responsive
pneumatic
Table 2: "MRT550RL includes MRT550H, MRTHRL & MRTG-1".
Monogram MRL1003 (Radial-Lok install spec), p.7, Figure 2, Table 2 ↗
Grip, hole and inspection gauges
RLS-1A
Radial-Lok grip gage and grip scale slide, assembly (grip gage RLS-1, grip scale slide GSS-1)
Checks: "Prior to installation, the grip length shall be checked with a grip gage" (§6.1). Borderline: "a min. grip condition be favored, (i.e. a - .225" thick structure reading uses a - 300 grip part)" (§4.1).
Monogram MRL1003 (Radial-Lok install spec), p.9, §6.1, Figure 4 ↗
MRLG-6
Hole gage (GO / NO GO)
Sizes: -6
Checks: "Holes shall be inspected using hole gages as shown in Figure 6 and limits as specified in Table 4. The "Go" gage shall pass completely through the prepared hole" (§5.1.4).
Monogram MRL1003 (Radial-Lok install spec), p.10, Figure 6, Table 4 ↗
MRLG-7
Hole gage (GO / NO GO)
Sizes: -7
Checks: "Holes shall be inspected using hole gages as shown in Figure 6 and limits as specified in Table 4. The "Go" gage shall pass completely through the prepared hole" (§5.1.4).
Monogram MRL1003 (Radial-Lok install spec), p.10, Figure 6, Table 4 ↗
MRLG-8
Hole gage (GO / NO GO)
Sizes: -8
Checks: "Holes shall be inspected using hole gages as shown in Figure 6 and limits as specified in Table 4. The "Go" gage shall pass completely through the prepared hole" (§5.1.4).
Monogram MRL1003 (Radial-Lok install spec), p.10, Figure 6, Table 4 ↗
MRLG-9
Hole gage (GO / NO GO)
Sizes: -9
Checks: "Holes shall be inspected using hole gages as shown in Figure 6 and limits as specified in Table 4. The "Go" gage shall pass completely through the prepared hole" (§5.1.4).
Monogram MRL1003 (Radial-Lok install spec), p.10, Figure 6, Table 4 ↗
MRLG-10
Hole gage (GO / NO GO)
Sizes: -10
Checks: "Holes shall be inspected using hole gages as shown in Figure 6 and limits as specified in Table 4. The "Go" gage shall pass completely through the prepared hole" (§5.1.4).
Monogram MRL1003 (Radial-Lok install spec), p.10, Figure 6, Table 4 ↗
MRLG-11
Hole gage (GO / NO GO)
Sizes: -11
Checks: "Holes shall be inspected using hole gages as shown in Figure 6 and limits as specified in Table 4. The "Go" gage shall pass completely through the prepared hole" (§5.1.4).
Monogram MRL1003 (Radial-Lok install spec), p.10, Figure 6, Table 4 ↗
MRLG-12
Hole gage (GO / NO GO)
Sizes: -12
Checks: "Holes shall be inspected using hole gages as shown in Figure 6 and limits as specified in Table 4. The "Go" gage shall pass completely through the prepared hole" (§5.1.4).
Monogram MRL1003 (Radial-Lok install spec), p.10, Figure 6, Table 4 ↗
MGFRL-6 / MGPRL-6
Flush head barrel gage / protruding head leaf gage
Sizes: -6
Checks: Screw break-off: "When checking high break-off ... if the gage rocks, the break-off is too high"; low break-off: "if gage does not rock, the break-off is too low" (Figure 9).
Limits: Per product drawing (Table 6).
Monogram MRL1003 (Radial-Lok install spec), p.13, Figure 9, Table 6 ↗
MGFRL-7 / MGPRL-7
Flush head barrel gage / protruding head leaf gage
Sizes: -7
Checks: Screw break-off: "When checking high break-off ... if the gage rocks, the break-off is too high"; low break-off: "if gage does not rock, the break-off is too low" (Figure 9).
Limits: Per product drawing (Table 6).
Monogram MRL1003 (Radial-Lok install spec), p.13, Figure 9, Table 6 ↗
MGFRL-8 / MGPRL-8
Flush head barrel gage / protruding head leaf gage
Sizes: -8
Checks: Screw break-off: "When checking high break-off ... if the gage rocks, the break-off is too high"; low break-off: "if gage does not rock, the break-off is too low" (Figure 9).
Limits: Per product drawing (Table 6).
Monogram MRL1003 (Radial-Lok install spec), p.13, Figure 9, Table 6 ↗
MGFRL-9 / MGPRL-9
Flush head barrel gage / protruding head leaf gage
Sizes: -9
Checks: Screw break-off: "When checking high break-off ... if the gage rocks, the break-off is too high"; low break-off: "if gage does not rock, the break-off is too low" (Figure 9).
Limits: Per product drawing (Table 6).
Monogram MRL1003 (Radial-Lok install spec), p.13, Figure 9, Table 6 ↗
MGFRL-10 / MGPRL-10
Flush head barrel gage / protruding head leaf gage
Sizes: -10
Checks: Screw break-off: "When checking high break-off ... if the gage rocks, the break-off is too high"; low break-off: "if gage does not rock, the break-off is too low" (Figure 9).
Limits: Per product drawing (Table 6).
Monogram MRL1003 (Radial-Lok install spec), p.13, Figure 9, Table 6 ↗
MGFRL-11 / MGPRL-11
Flush head barrel gage / protruding head leaf gage
Sizes: -11
Checks: Screw break-off: "When checking high break-off ... if the gage rocks, the break-off is too high"; low break-off: "if gage does not rock, the break-off is too low" (Figure 9).
Limits: Per product drawing (Table 6).
Monogram MRL1003 (Radial-Lok install spec), p.13, Figure 9, Table 6 ↗
MGFRL-12 / MGPRL-12
Flush head barrel gage / protruding head leaf gage
Sizes: -12
Checks: Screw break-off: "When checking high break-off ... if the gage rocks, the break-off is too high"; low break-off: "if gage does not rock, the break-off is too low" (Figure 9).
Limits: Per product drawing (Table 6).
Monogram MRL1003 (Radial-Lok install spec), p.13, Figure 9, Table 6 ↗
Tooling source notes
- MRL1003 §7.5: "In those instances where special driving tools are adopted by the user, wrenching speed of this tooling shall not exceed 600 RPM." §4.3: "only the approved tools listed in Tables 1 and 2 ... be used".Specification, not interview: Monogram MRL1003.
- Alternative tooling works in practice: roughly 500 RPM with the right torque and fittings, and shops fabricate the fittings in house. Check it against the manufacturer's speed limit for user-adopted tools before relying on it.Installer interview (aerospace tool services), 2026-09-25. Field experience, not a specification.
- Monogram factory tooling was quoted at 23 to 24 weeks lead time. Order tooling with, or before, the first fasteners.Installer interview (aerospace tool services), 2026-09-25. Field experience, not a specification.
Removal (drill-out)Published procedure
Monogram MRL1003 (Radial-Lok), §8.0, Figure 10 and Table 7
- “Radial-Lok blind fasteners can be removed using the tooling shown in Figure 10 and Table 7 of this specification. Complete kits are available from Monogram Aerospace Fasteners. Contact factory for details.” Monogram MRL1003 (Radial-Lok install spec), p.5, §8.1 ↗
- “Screw protrusion shall be shaved flush prior to drilling.” Monogram MRL1003 (Radial-Lok install spec), p.15, Figure 10, Removal Tool ↗
- “A complete tool consists of the air motor middle (#RM3098), a nose piece module (see chart), and a carbide star drill (RM3050-( )).” Monogram MRL1003 (Radial-Lok install spec), p.14, Table 7, Removal Data ↗
Cautions
- “If a fastener has been removed, the same diameter Radial-Lok can be reinstalled provided the hole has not been damaged. In the event that the hole has been damaged, the next larger diameter Radial-Lok shall be used (NOTE: for flush head fasteners the countersink will have to be deepened).” Monogram MRL1003 (Radial-Lok install spec), p.3, §4.6 ↗
- “This kit is used to removed alloy steel, titanium and A-286 Visu-Loks or A-286 and titanium Composi-Lok and Radial-Lok fasteners. To remove H-11 and similar material, contact factory for details.” Monogram MRL1003 (Radial-Lok install spec), p.14, Table 7, Removal Data ↗
Removal data (Table 7)
| Nominal diameter | Nose piece module | Carbide star drill | Drill size dia. | Depth gage |
|---|---|---|---|---|
| -6 (.1975) | RM3081-6 | RC3050-6 | .1890 | RC3031-6 |
| -7 (.2265) | RM3081-7 | RC3050-7 | .2180 | RC3031-7 |
| -8 (.2585) | RM3081-8 | RC3050-8 | .2500 | RC3031-8 |
| -9 (.2885) | RM3081-9 | RC3050-9 | .2810 | RC3031-9 |
| -10 (.3105) | RM3153-10 | RC3050-10 | .3020 | RC3156-10 |
| -11 (.3425) | RM3153-11 | RC3050-11 | .3320 | RC3156-11 |
| -12 (.3735) | RM3153-12 | RC3050-12 | .3590 | RC3156-12 |
Monogram MRL1003 (Radial-Lok install spec), p.14, Table 7, Removal Data ↗
None of the removal procedures on file gives a composite-specific removal caution. The Monogram specs address composite at the hole instead: holes "reasonably round and free from burrs (metallic structure) and delamination (graphite/epoxy type structure)" (MBF2003 §5.1).
Tool tables are the manufacturer's as published in the cited revision; confirm current tool PNs with the manufacturer or distributor before purchase. Not a certified process authority: install and remove per the OEM process specification.
Next · Step 4: Order
Put the tooling on the RFQ