Shop verification card
Radial-Lok
Monogram · Blind bolt · MRL3210 (low profile protruding head) / MRL3212 (100° flush tension head) · e.g. MRL3212-06-500
speclok.com
11/16/2026
Install sequence
1. Inserted, tool placed
2. Nut body forced into the expansion sleeve
3. Blind head formed, screw fractures
Traced from Monogram Radial-Lok brochure, p.2, Installation Sequence. Not to scale.
Before you install
- Diameters offered: 3/16, 1/4, 5/16, 3/8"
- Tool: Monogram installation tooling (install spec MRL1003)
- Proprietary system required.
- Training: Not stated in the cited documents.
- Lead-time risk: High
Installed preload
- Minimum preload per diameter (brochure table): -6: 700 lb · -7: 700 lb · -8: 1,000 lb · -9: 1,000 lb · -10: 1,500 lb · -11: 1,500 lb · -12: 2,000 lb
- 3/16" Ti (MRL3212-06), catalog chart: 700 lb minimum · 1,000 lb typical
The best-published preload in the catalog: an explicit per-size minimum preload column in the Radial-Lok brochure. Values are fastener capabilities, not joint requirements.
Gauge kit (published part numbers)
| Gauge | Sizes | Checks / limits | Source |
|---|---|---|---|
| RLS-1A | all | Radial-Lok grip gage and grip scale slide, assembly (grip gage RLS-1, grip scale slide GSS-1) | Monogram MRL1003 (Radial-Lok install spec), p.9, §6.1, Figure 4 |
| MRLG-6 | -6 | Hole gage (GO / NO GO) | Monogram MRL1003 (Radial-Lok install spec), p.10, Figure 6, Table 4 |
| MRLG-7 | -7 | Hole gage (GO / NO GO) | Monogram MRL1003 (Radial-Lok install spec), p.10, Figure 6, Table 4 |
| MRLG-8 | -8 | Hole gage (GO / NO GO) | Monogram MRL1003 (Radial-Lok install spec), p.10, Figure 6, Table 4 |
| MRLG-9 | -9 | Hole gage (GO / NO GO) | Monogram MRL1003 (Radial-Lok install spec), p.10, Figure 6, Table 4 |
| MRLG-10 | -10 | Hole gage (GO / NO GO) | Monogram MRL1003 (Radial-Lok install spec), p.10, Figure 6, Table 4 |
| MRLG-11 | -11 | Hole gage (GO / NO GO) | Monogram MRL1003 (Radial-Lok install spec), p.10, Figure 6, Table 4 |
| MRLG-12 | -12 | Hole gage (GO / NO GO) | Monogram MRL1003 (Radial-Lok install spec), p.10, Figure 6, Table 4 |
| MGFRL-6 / MGPRL-6 | -6 | Flush head barrel gage / protruding head leaf gage · Per product drawing (Table 6). | Monogram MRL1003 (Radial-Lok install spec), p.13, Figure 9, Table 6 |
| MGFRL-7 / MGPRL-7 | -7 | Flush head barrel gage / protruding head leaf gage · Per product drawing (Table 6). | Monogram MRL1003 (Radial-Lok install spec), p.13, Figure 9, Table 6 |
| MGFRL-8 / MGPRL-8 | -8 | Flush head barrel gage / protruding head leaf gage · Per product drawing (Table 6). | Monogram MRL1003 (Radial-Lok install spec), p.13, Figure 9, Table 6 |
| MGFRL-9 / MGPRL-9 | -9 | Flush head barrel gage / protruding head leaf gage · Per product drawing (Table 6). | Monogram MRL1003 (Radial-Lok install spec), p.13, Figure 9, Table 6 |
| MGFRL-10 / MGPRL-10 | -10 | Flush head barrel gage / protruding head leaf gage · Per product drawing (Table 6). | Monogram MRL1003 (Radial-Lok install spec), p.13, Figure 9, Table 6 |
| MGFRL-11 / MGPRL-11 | -11 | Flush head barrel gage / protruding head leaf gage · Per product drawing (Table 6). | Monogram MRL1003 (Radial-Lok install spec), p.13, Figure 9, Table 6 |
| MGFRL-12 / MGPRL-12 | -12 | Flush head barrel gage / protruding head leaf gage · Per product drawing (Table 6). | Monogram MRL1003 (Radial-Lok install spec), p.13, Figure 9, Table 6 |
Removal
Published: Monogram MRL1003 (Radial-Lok), §8.0, Figure 10 and Table 7. If a fastener has been removed, the same diameter Radial-Lok can be reinstalled provided the hole has not been damaged. In the event that the hole has been damaged, the next larger diameter Radial-Lok shall be used (NOTE: for flush head fasteners the countersink will have to be deepened). Steps: speclok.com/tooling/radial-lok#removal
Accept / reject after install
- Unique blind-side check: footprint diameter J must meet the minimum per MRL1003 Table 3 (-6: .290" up to -12: .560"); an undersized footprint is positive indication of improper installation.
- Screw break-off limits per product drawing (MRL3210: -6/-7 +.275"/+.075" above surface, up to -12 +.335"/+.135").
- Blind-side protrusion K max .500"-.625" by size.
- Mandatory hole-edge chamfer or fillet radius before install (MRL1003 Table 3). No seating-torque table exists for this family.
Check gauges
- MRLG-6 through MRLG-12 GO/NO-GO hole gauges, required before installation (GO must pass completely through).
- MGFRL flush barrel and MGPRL protruding leaf break-off gauges (rock / no-rock).
Sources: MRL1003 installation spec · Radial-Lok brochure (preload table) · MRL3210 drawing. Acceptance limits belong to the controlling spec: verify against your program's process documentation before use on hardware.
Sources
Reference only: the controlling drawing, its process spec and the manufacturer's installation instructions govern. How to use these answers