← Tooling compatibility finder
H681-5C
H681 pulling head, Universal Head / Countersunk Head (NASM20426) · Nose / pulling head · Standard
H681-5C installs CherryLOCK -5 and 1 more family, per the fastener's process document. Cherry CA-1013 p.9 ↗
3D model not available: dimensions not published. 3D library
Fastener process documents that name it2
Other brands' equivalents0 statements
No cross-brand statement on file for these tools. Not documented is not the same as incompatible.
Sources1
- Cherry CA-1013 (CherryLOCK process manual), p.9, Selection Of Proper Hydro-shift Pulling Head, H681 Series ↗
- "A separate pulling head is required for each diameter CherryLOCK rivet. It is acceptable that countersunk (C) pulling heads be used for installing both universal and countersunk head CherryLOCK rivets." Dims A and B as drawn on the CA-1013 p.9 figure.
Tool catalogs are the manufacturers' as published in the cited edition; confirm current PNs with the tool maker before purchase. Install per the OEM process specification.
Published dimensions3 · for envelope CAD
No dimensions are printed for this item in the catalogs on file.
As printed in the fastener process documents
- Dim. A: .269" (CherryLOCK, Standard blind rivet (NAS1398/NAS1399 wiredraw), Cherry CA-1013 (CherryLOCK process manual), p.9, Selection Of Proper Hydro-shift Pulling Head, H681 Series ↗)
- Dim. B: .352" (CherryLOCK, Standard blind rivet (NAS1398/NAS1399 wiredraw), Cherry CA-1013 (CherryLOCK process manual), p.9, Selection Of Proper Hydro-shift Pulling Head, H681 Series ↗)
- Series length, as dimensioned: 2-9/16" (CherryLOCK, Standard blind rivet (NAS1398/NAS1399 wiredraw), Cherry CA-1013 (CherryLOCK process manual), p.9, Selection Of Proper Hydro-shift Pulling Head, H681 Series ↗)
Only dimensions a document prints are listed, with the feature each one measures. A length read from a part number by a rule the cited chart prints is marked "Not printed as a number". None of these catalogs publishes nose tip or anvil geometry detailed enough to machine from.
Reference only: the controlling drawing, its process spec and the manufacturer's installation instructions govern. How to use these answers
Next step
Free to ask. A person at SpecLok replies by email. You only pay the supplier if you accept a quote.