Shop verification card
Visu-Lok
Monogram · Hex-drive blind bolt · PLT5 series · e.g. PLT5170-06-05 (100° flush head, titanium) / PLT5270 (hex head, titanium)
speclok.com
11/16/2026
Install sequence
1. Inserted, tool placed
2. Screw torqued, head starts
3. Large blind head completed
4. Screw fractures, pintail and drive nut discarded
Traced from Monogram Visu-Lok II brochure, p.3, How They Work. Not to scale.
Before you install
- Diameters offered: 5/32, 3/16, 1/4, 5/16, 3/8"
- Tool: Monogram installation tool engaging wrench flats and DRIVE NUT (Visu-Lok II brochure p.3); "use of existing NAS1675 tooling" (Monogram catalog)
- Proprietary system required.
- Training: Not stated in the cited documents.
- Lead-time risk: High
Installed preload
- Guaranteed minimum preload: 20% of minimum ultimate tensile strength (Visu-Lok II brochure); 3/16" Ti (PLT5170-06): 280 lb min · 1,200 lb typical (Monogram catalog chart)
This is the number behind the "Visu" self-inspection claim: break-off height gauging indicates correct grip, and a specified seating torque (4 in-lb at -5 to 30 in-lb at -12, PLT5002 Table 12) indicates clamp-up. Flush heads carry small recesses specifically so seating torque can be checked after install.
Gauge kit (published part numbers)
| Gauge | Sizes | Checks / limits | Source |
|---|---|---|---|
| VLS-1A | all | Visu-Lok grip gage and grip scale slide, assembly (grip gage VLS-1, grip scale slide GSS-1) | Monogram PLT5002 Rev N (Visu-Lok II install spec), p.14, §6.1, Figure 10 |
| MGF-05 | -5 | Flush head round gage · +.020/-.068 | Monogram PLT5002 Rev N (Visu-Lok II install spec), p.19, Table 11 |
| MGF-06 | -6 | Flush head round gage · +.015/-.073 | Monogram PLT5002 Rev N (Visu-Lok II install spec), p.19, Table 11 |
| MGF-08 | -8 | Flush head round gage · +.010/-.078 | Monogram PLT5002 Rev N (Visu-Lok II install spec), p.19, Table 11 |
| MGF-10 | -10 | Flush head round gage · +.010/-.083 | Monogram PLT5002 Rev N (Visu-Lok II install spec), p.19, Table 11 |
| MGF-12 | -12 | Flush head round gage · +.010/-.093 | Monogram PLT5002 Rev N (Visu-Lok II install spec), p.19, Table 11 |
| MGP-05 | -5 | Protruding head leaf gage · +.088/+.000 | Monogram PLT5002 Rev N (Visu-Lok II install spec), p.19, Table 11 |
| MGP-06 | -6 | Protruding head leaf gage · +.098/+.010 | Monogram PLT5002 Rev N (Visu-Lok II install spec), p.19, Table 11 |
| MGP-08 | -8 | Protruding head leaf gage · +.135/+.047 | Monogram PLT5002 Rev N (Visu-Lok II install spec), p.19, Table 11 |
| MGP-10 | -10 | Protruding head leaf gage · +.146/+.043 | Monogram PLT5002 Rev N (Visu-Lok II install spec), p.19, Table 11 |
| MGP-12 | -12 | Protruding head leaf gage · +.152/+.049 | Monogram PLT5002 Rev N (Visu-Lok II install spec), p.19, Table 11 |
| MHTFDN-( ) / MHTPDN-( ) | all | Torque adaptors, -5 through -12 | Monogram PLT5002 Rev N (Visu-Lok II install spec), p.20, Table 12 |
Removal
Published: Monogram PLT5002 Rev N (Visu-Lok II), §8.0 and Figure 9 (RK5000 kit). If a fastener has been removed, the same diameter Visu-Lok II can be reinstalled provided the hole has not been damaged. In the event that the hole has been damaged, the next larger diameter Visu-Lok II should be used. (Note: for flush head fasteners the countersink will have to be deepened). Steps: speclok.com/tooling/visu-lok#removal
Accept / reject after install
- Stem break-off position vs head/skin per PLT5002 Table 11, e.g. PLT5170 flush: -5 +.020"/-.068", -6 +.015"/-.073", -8 +.010"/-.078"; protruding PLT5270: -6 +.098"/+.010".
- Break too high = fastener too long; too low = too short. Remove, re-check grip, replace.
- Seating-torque check (counter-clockwise, do not exceed) confirms clamp.
Check gauges
- Flush head round gages (MGF, MGFA, MGFB, MGR) and protruding head leaf gages (MGP), by part number and size (PLT 5002 Table 11). Gage rocks = break-off too high; does not rock on the low end = too low (PLT 5002).
- Torque adaptors MHTFDN-( ) and MHTPDN-( ), -5 through -12, for the seating torque check (PLT 5002 Table 12).
Sources: PLT5002 installation spec · Visu-Lok II brochure · Monogram catalog (preload chart). Acceptance limits belong to the controlling spec: verify against your program's process documentation before use on hardware.
Sources
Reference only: the controlling drawing, its process spec and the manufacturer's installation instructions govern. How to use these answers