◈SpecLok
  • Part number
  • Find a tool
  • Get quotes
  • Learn
More ▾

Learn

  • How specialty fasteners work
  • Explore fasteners
  • Catalog
  • AN / MS / NAS hardware
  • 3D model library
  • Compare side by side
  • Installation tooling guide
  • Design calculators
  • All articles

Select

  • Joint selector
  • Part-number decoder
  • Part-number cross reference
  • Which tool installs this part
  • Part-number index
  • Grip length planner
  • Hole schedule & grip review
  • BOM decoder

Quote and procure

  • Your quote
  • Request a tool: buy, rent or repair
  • Installation tooling
  • Preview the RFQ document
  • Your quote requests
  • Inventory and certs
  • The sourcing reality

Learn

  • How specialty fasteners work
  • Explore fasteners
  • Catalog
  • AN / MS / NAS hardware
  • 3D model library
  • Compare side by side
  • Installation tooling guide
  • Design calculators
  • All articles

Select

  • Joint selector
  • Part-number decoder
  • Part-number cross reference
  • Which tool installs this part
  • Part-number index
  • Grip length planner
  • Hole schedule & grip review
  • BOM decoder

Quote and procure

  • Your quote
  • Request a tool: buy, rent or repair
  • Installation tooling
  • Preview the RFQ document
  • Your quote requests
  • Inventory and certs
  • The sourcing reality

Aerospace Fasteners

SpecLok · a fastener-selection aid, not a certified design authority. Always verify against the controlling spec, OEM process, and your stress group.

Collects anonymous usage data to improve selection and sourcing. No personal info unless you add an email to a quote request.

Your account

← Visu-Lok

Shop verification card

Visu-Lok

Monogram · Hex-drive blind bolt · PLT5 series · e.g. PLT5170-06-05 (100° flush head, titanium) / PLT5270 (hex head, titanium)

speclok.com
11/16/2026

Install sequence

  1. 1. Inserted, tool placed

  2. 2. Screw torqued, head starts

  3. 3. Large blind head completed

  4. 4. Screw fractures, pintail and drive nut discarded

Traced from Monogram Visu-Lok II brochure, p.3, How They Work. Not to scale.

Before you install

  • Diameters offered: 5/32, 3/16, 1/4, 5/16, 3/8"
  • Tool: Monogram installation tool engaging wrench flats and DRIVE NUT (Visu-Lok II brochure p.3); "use of existing NAS1675 tooling" (Monogram catalog)
  • Proprietary system required.
  • Training: Not stated in the cited documents.
  • Lead-time risk: High

Installed preload

  • Guaranteed minimum preload: 20% of minimum ultimate tensile strength (Visu-Lok II brochure); 3/16" Ti (PLT5170-06): 280 lb min · 1,200 lb typical (Monogram catalog chart)

This is the number behind the "Visu" self-inspection claim: break-off height gauging indicates correct grip, and a specified seating torque (4 in-lb at -5 to 30 in-lb at -12, PLT5002 Table 12) indicates clamp-up. Flush heads carry small recesses specifically so seating torque can be checked after install.

Gauge kit (published part numbers)

GaugeSizesChecks / limitsSource
VLS-1AallVisu-Lok grip gage and grip scale slide, assembly (grip gage VLS-1, grip scale slide GSS-1)Monogram PLT5002 Rev N (Visu-Lok II install spec), p.14, §6.1, Figure 10
MGF-05-5Flush head round gage · +.020/-.068Monogram PLT5002 Rev N (Visu-Lok II install spec), p.19, Table 11
MGF-06-6Flush head round gage · +.015/-.073Monogram PLT5002 Rev N (Visu-Lok II install spec), p.19, Table 11
MGF-08-8Flush head round gage · +.010/-.078Monogram PLT5002 Rev N (Visu-Lok II install spec), p.19, Table 11
MGF-10-10Flush head round gage · +.010/-.083Monogram PLT5002 Rev N (Visu-Lok II install spec), p.19, Table 11
MGF-12-12Flush head round gage · +.010/-.093Monogram PLT5002 Rev N (Visu-Lok II install spec), p.19, Table 11
MGP-05-5Protruding head leaf gage · +.088/+.000Monogram PLT5002 Rev N (Visu-Lok II install spec), p.19, Table 11
MGP-06-6Protruding head leaf gage · +.098/+.010Monogram PLT5002 Rev N (Visu-Lok II install spec), p.19, Table 11
MGP-08-8Protruding head leaf gage · +.135/+.047Monogram PLT5002 Rev N (Visu-Lok II install spec), p.19, Table 11
MGP-10-10Protruding head leaf gage · +.146/+.043Monogram PLT5002 Rev N (Visu-Lok II install spec), p.19, Table 11
MGP-12-12Protruding head leaf gage · +.152/+.049Monogram PLT5002 Rev N (Visu-Lok II install spec), p.19, Table 11
MHTFDN-( ) / MHTPDN-( )allTorque adaptors, -5 through -12Monogram PLT5002 Rev N (Visu-Lok II install spec), p.20, Table 12

Removal

Published: Monogram PLT5002 Rev N (Visu-Lok II), §8.0 and Figure 9 (RK5000 kit). If a fastener has been removed, the same diameter Visu-Lok II can be reinstalled provided the hole has not been damaged. In the event that the hole has been damaged, the next larger diameter Visu-Lok II should be used. (Note: for flush head fasteners the countersink will have to be deepened). Steps: speclok.com/tooling/visu-lok#removal

Accept / reject after install

  • Stem break-off position vs head/skin per PLT5002 Table 11, e.g. PLT5170 flush: -5 +.020"/-.068", -6 +.015"/-.073", -8 +.010"/-.078"; protruding PLT5270: -6 +.098"/+.010".
  • Break too high = fastener too long; too low = too short. Remove, re-check grip, replace.
  • Seating-torque check (counter-clockwise, do not exceed) confirms clamp.

Check gauges

  • Flush head round gages (MGF, MGFA, MGFB, MGR) and protruding head leaf gages (MGP), by part number and size (PLT 5002 Table 11). Gage rocks = break-off too high; does not rock on the low end = too low (PLT 5002).
  • Torque adaptors MHTFDN-( ) and MHTPDN-( ), -5 through -12, for the seating torque check (PLT 5002 Table 12).

Sources: PLT5002 installation spec · Visu-Lok II brochure · Monogram catalog (preload chart). Acceptance limits belong to the controlling spec: verify against your program's process documentation before use on hardware.

Sources

3
  1. Monogram Visu-Lok II brochure
  2. PLT5002 installation spec
  3. Monogram catalog (preload chart)

Reference only: the controlling drawing, its process spec and the manufacturer's installation instructions govern. How to use these answers