Shop verification card
Huck Magna-Grip (industrial)
Howmet/Huck · Lockbolt (swaged collar) · MGP[head]-[mat][dia]-[grip] + collar MGC… · e.g. MGPB-R8-10G
speclok.com
11/16/2026
Install sequence
1. Pin inserted, collar placed
2. Tool pulls the pin
3. Collar swaged
4. Pintail breaks flush
Traced from Howmet Huck Magna-Grip brochure, p.3, Installation Sequence. Not to scale.
Before you install
- Diameters offered: 3/16, 1/4, 5/16, 3/8"
- Tool: Huck installation tool (brochure)
- Proprietary system required.
- Training: Not stated in the cited documents.
- Lead-time risk: Medium
Installed preload
- Installed clamp, aluminum pin (min/typ): 3/16": 550/800 lb · 1/4": 950/1,400 lb · 5/16": 1,600/2,200 lb · 3/8": 2,400/3,200 lb
- Installed clamp, steel pin (min/typ): 3/16": 1,025/1,500 lb · 1/4": 1,350/2,000 lb · 5/16": 2,300/2,900 lb · 3/8": 3,200/4,000 lb
Installed values in nominal grip, from the Huck Magna-Grip brochure. One of the few families that publishes clamp directly.
Removal
No published removal procedure found; follow the manufacturer's instructions. Steps: speclok.com/tooling/magna-grip#removal
Accept / reject after install
- Core pin flush with the collar = properly installed (visual completion criterion).
- Lock witness marks: up to two within the collar acceptable; three is a reject.
- Installed-collar inspection dimensions per diameter (brochure Inspection Data table): e.g. A max .062"-.250" by size.
Check gauges
- Huck grip and pin-position/swage gages per Product Bulletins PB162 and PB509 (per-diameter gage tables not freely retrievable; confirm gage PN with Howmet).
Sources: Magna-Grip brochure (Howmet) · HFS tooling catalog (PB162/PB509). Acceptance limits belong to the controlling spec: verify against your program's process documentation before use on hardware.
Sources
Reference only: the controlling drawing, its process spec and the manufacturer's installation instructions govern. How to use these answers