◈SpecLok
  • Part number
  • Find a tool
  • Get quotes
  • Learn
More ▾

Learn

  • How specialty fasteners work
  • Explore fasteners
  • Catalog
  • AN / MS / NAS hardware
  • 3D model library
  • Compare side by side
  • Installation tooling guide
  • Design calculators
  • All articles

Select

  • Joint selector
  • Part-number decoder
  • Part-number cross reference
  • Which tool installs this part
  • Part-number index
  • Grip length planner
  • Hole schedule & grip review
  • BOM decoder

Quote and procure

  • Your quote
  • Request a tool: buy, rent or repair
  • Installation tooling
  • Preview the RFQ document
  • Your quote requests
  • Inventory and certs
  • The sourcing reality

Learn

  • How specialty fasteners work
  • Explore fasteners
  • Catalog
  • AN / MS / NAS hardware
  • 3D model library
  • Compare side by side
  • Installation tooling guide
  • Design calculators
  • All articles

Select

  • Joint selector
  • Part-number decoder
  • Part-number cross reference
  • Which tool installs this part
  • Part-number index
  • Grip length planner
  • Hole schedule & grip review
  • BOM decoder

Quote and procure

  • Your quote
  • Request a tool: buy, rent or repair
  • Installation tooling
  • Preview the RFQ document
  • Your quote requests
  • Inventory and certs
  • The sourcing reality

Aerospace Fasteners

SpecLok · a fastener-selection aid, not a certified design authority. Always verify against the controlling spec, OEM process, and your stress group.

Collects anonymous usage data to improve selection and sourcing. No personal info unless you add an email to a quote request.

Your account

← CherryMAX

Shop verification card

CherryMAX

Cherry · Blind rivet · CR3xxx · e.g. CR3242-6-04

speclok.com
11/16/2026

Install sequence

  1. 1. Inserted

  2. 2. Bulbed blind head forms

  3. 3. Shear ring shears, collar seats

  4. 4. Locked, stem breaks flush

Traced from Cherry CA-1011 (CherryMAX), p.3, Installation. Not to scale.

Before you install

  • Diameters offered: 1/8, 5/32, 3/16, 1/4"
  • Tool: Cherry hand riveters and pneumatic-hydraulic riveters with pulling heads (CA-1011 tooling section)
  • Standard shop tooling.
  • Training: Not stated in the cited documents.
  • Lead-time risk: Low

Installed preload

Not published. CA-1011 catalog, CA-1015 process manual, and procurement spec PS-CMR-3000 give shear, tensile, fatigue and flushness acceptance only; no preload figure exists for this family.

Gauge kit (published part numbers)

GaugeSizesChecks / limitsSource
269C3allGrip gage for CherryMAX & CherryLOCK rivetsCherry CA-1015 (CherryMAX process manual), p.11, Correct Grip Measurement
T172-4 / T172-400-4T172 GO/NO-GO hole gageCherry CA-1015 (CherryMAX process manual), p.7, Hole Preparation
T172-5 / T172-500-5T172 GO/NO-GO hole gageCherry CA-1015 (CherryMAX process manual), p.7, Hole Preparation
T172-6 / T172-600-6T172 GO/NO-GO hole gageCherry CA-1015 (CherryMAX process manual), p.7, Hole Preparation
T172-8 / T172-800-8T172 GO/NO-GO hole gageCherry CA-1015 (CherryMAX process manual), p.7, Hole Preparation

Removal

Published: Cherry CA-1015 (CherryMAX process manual), Rivet Removal. Caution: DO NOT drill completely through the rivet sleeve to remove a rivet as this may enlarge the hole. Steps: speclok.com/tooling/cherrymax#removal

Accept / reject after install

  • Stem flushness vs top of head, per diameter (above / below max): -4: .010"/.015"; -5: .010"/.020"; -6: .010"/.020"; -8: .015"/.025" (PS-CMR-3000 Table VIII).
  • Locking collar flush with top of head within ±.005"; collar flash .010" max.
  • Blind-side head formation compared against the published acceptable-formation pictorials; stretch marks acceptable.
  • Grip and material marking on the head must remain readable after install.
  • Stem may be shaved to the top of the sleeve only if protrusion was within limits first; shaving into the head is not allowed (CA-1015).

Check gauges

  • 269C3 grip selector gage (NSN 5210-00-255-7544): measures stack through the hole before install.
  • T172 GO/NO-GO hole gages (T172-4/-5/-6/-8 nominal; -400/-500/-600/-800 oversize).
  • Installed flushness is a dimensional/visual check; no dedicated installed gauge is published.

Sources: CA-1011 catalog · CA-1015 process manual · PS-CMR-3000. Acceptance limits belong to the controlling spec: verify against your program's process documentation before use on hardware.

Sources

3
  1. Cherry CA-1011 (CherryMAX catalog)
  2. CA-1015 process manual
  3. PS-CMR-3000

Reference only: the controlling drawing, its process spec and the manufacturer's installation instructions govern. How to use these answers